The DCM test (EN580) uses dichloromethane solvent to detect un-fused powder on the chamfered pipe surface. Loose powder indicates insufficient fusion or gelation.
The DCM test is more stringent than the ASTM acetone test, requiring a narrow processing window for optimal gelation without entrapped air, critical for pipe integrity.